windchill¶
-
metpy.calc.
windchill
(temperature, speed, face_level_winds=False, mask_undefined=True)[source]¶ Calculate the Wind Chill Temperature Index (WCTI).
Calculates WCTI from the current temperature and wind speed using the formula outlined by the FCM [FCMR192003].
Specifically, these formulas assume that wind speed is measured at 10m. If, instead, the speeds are measured at face level, the winds need to be multiplied by a factor of 1.5 (this can be done by specifying face_level_winds as True.)
Parameters: - temperature (pint.Quantity) – The air temperature
- speed (pint.Quantity) – The wind speed at 10m. If instead the winds are at face level, face_level_winds should be set to True and the 1.5 multiplicative correction will be applied automatically.
- face_level_winds (bool, optional) – A flag indicating whether the wind speeds were measured at facial level instead of 10m, thus requiring a correction. Defaults to False.
- mask_undefined (bool, optional) – A flag indicating whether a masked array should be returned with values where wind chill is undefined masked. These are values where the temperature > 50F or wind speed <= 3 miles per hour. Defaults to True.
Returns: pint.Quantity – The corresponding Wind Chill Temperature Index value(s)
See also