psychrometric_vapor_pressure_wet

metpy.calc.psychrometric_vapor_pressure_wet(pressure, dry_bulb_temperature, wet_bulb_temperature, psychrometer_coefficient=None)[source]

Calculate the vapor pressure with wet bulb and dry bulb temperatures.

This uses a psychrometric relationship as outlined in [WMO8], with coefficients from [Fan1987].

Parameters
  • pressure (pint.Quantity) – Total atmospheric pressure

  • dry_bulb_temperature (pint.Quantity) – Dry bulb temperature

  • wet_bulb_temperature (pint.Quantity) – Wet bulb temperature

  • psychrometer_coefficient (pint.Quantity, optional) – Psychrometer coefficient. Defaults to 6.21e-4 K^-1.

Returns

pint.Quantity – Vapor pressure

Notes

\[e' = e'_w(T_w) - A p (T - T_w)\]
  • \(e'\) is vapor pressure

  • \(e'_w(T_w)\) is the saturation vapor pressure with respect to water at temperature \(T_w\)

  • \(p\) is the pressure of the wet bulb

  • \(T\) is the temperature of the dry bulb

  • \(T_w\) is the temperature of the wet bulb

  • \(A\) is the psychrometer coefficient

Psychrometer coefficient depends on the specific instrument being used and the ventilation of the instrument.

Changed in version 1.0: Changed signature from (dry_bulb_temperature, wet_bulb_temperature, pressure, psychrometer_coefficient)