(dry_bulb_temperature, web_bulb_temperature, pressure, **kwargs)[source]¶ Calculate the relative humidity with wet bulb and dry bulb temperatures.
Parameters: - dry_bulb_temperature (pint.Quantity) – Dry bulb temperature
- web_bulb_temperature (pint.Quantity) – Wet bulb temperature
- pressure (pint.Quantity) – Total atmospheric pressure
Returns: pint.Quantity – Relative humidity
Notes
\[RH = 100 \frac{e}{e_s}\]- \(RH\) is relative humidity
- \(e\) is vapor pressure from the wet psychrometric calculation
- \(e_s\) is the saturation vapor pressure
References
[10] WMO GUIDE TO METEOROLOGICAL INSTRUMENTS AND METHODS OF OBSERVATION WMO-No.8 (2008 edition, Updated in 2010) : PART 4 https://www.wmo.int/pages/prog/www/IMOP/CIMO-Guide.html [11] Fan, Jinpeng. “Determination of the psychrometer coefficient A of the WMO reference psychrometer by comparison with a standard gravimetric hygrometer.” Journal of Atmospheric and Oceanic Technology 4.1 (1987): 239-244.