virtual_temperature¶
-
metpy.calc.
virtual_temperature
(temperature, mixing, molecular_weight_ratio=<Quantity(0.621980086, 'dimensionless')>)[source]¶ Calculate virtual temperature.
This calculation must be given an air parcel’s temperature and mixing ratio. The implementation uses the formula outlined in [Hobbs2006] pg.80.
- Parameters
temperature (
pint.Quantity
) – air temperaturemixing (
pint.Quantity
) – dimensionless mass mixing ratiomolecular_weight_ratio (
pint.Quantity
or float, optional) – The ratio of the molecular weight of the constituent gas to that assumed for air. Defaults to the ratio for water vapor to dry air. (\(\epsilon\approx0.622\)).
- Returns
pint.Quantity
– The corresponding virtual temperature of the parcel
Notes
\[T_v = T \frac{\text{w} + \epsilon}{\epsilon\,(1 + \text{w})}\]