saturation_equivalent_potential_temperature¶
- 
metpy.calc.saturation_equivalent_potential_temperature(pressure, temperature)[source]¶
- Calculate saturation equivalent potential temperature. - This calculation must be given an air parcel’s pressure and temperature. The implementation uses the formula outlined in [Bolton1980] for the equivalent potential temperature, and assumes a saturated process. - First, because we assume a saturated process, the temperature at the LCL is equivalent to the current temperature. Therefore the following equation \[T_{L}=\frac{1}{\frac{1}{T_{D}-56}+\frac{ln(T_{K}/T_{D})}{800}}+56\]- reduces to \[T_{L} = T_{K}\]- Then the potential temperature at the temperature/LCL is calculated: \[\theta_{DL}=T_{K}\left(\frac{1000}{p-e}\right)^k \left(\frac{T_{K}}{T_{L}}\right)^{.28r}\]- However, because \[T_{L} = T_{K}\]- it follows that \[\theta_{DL}=T_{K}\left(\frac{1000}{p-e}\right)^k\]- Both of these are used to calculate the final equivalent potential temperature: \[\theta_{E}=\theta_{DL}\exp\left[\left(\frac{3036.}{T_{K}} -1.78\right)*r(1+.448r)\right]\]- Parameters
- pressure (pint.Quantity) – Total atmospheric pressure 
- temperature (pint.Quantity) – Temperature of parcel 
 
- Returns
- pint.Quantity – The saturation equivalent potential temperature of the parcel 
 - Notes - [Bolton1980] formula for Theta-e is used (for saturated case), since according to [DaviesJones2009] it is the most accurate non-iterative formulation available.