lcl¶
- 
metpy.calc.lcl(pressure, temperature, dewpt, max_iters=50, eps=1e-05)[source]¶
- Calculate the lifted condensation level (LCL) using from the starting point. - The starting state for the parcel is defined by temperature, dewpt, and pressure. - Parameters
- pressure (pint.Quantity) – The starting atmospheric pressure 
- temperature (pint.Quantity) – The starting temperature 
- dewpt (pint.Quantity) – The starting dew point 
 
- Returns
- (pint.Quantity, pint.Quantity) – The LCL pressure and temperature 
- Other Parameters
- max_iters (int, optional) – The maximum number of iterations to use in calculation, defaults to 50. 
- eps (float, optional) – The desired relative error in the calculated value, defaults to 1e-5. 
 
 - See also - Notes - This function is implemented using an iterative approach to solve for the LCL. The basic algorithm is: - Find the dew point from the LCL pressure and starting mixing ratio 
- Find the LCL pressure from the starting temperature and dewpoint 
- Iterate until convergence 
 - The function is guaranteed to finish by virtue of the max_iters counter. 
 